MIRAGE 1705 · TRIPLE-CHECK TAKEOFF (REV 2026-07-20 CAD) ====================================================================== PASS envelope · CORRECTED joists/int/unit SF · see TAKEOFF-FRAMING-TRUTH.txt Geometry: 100×110×5 · H=64' · GBA=55,000 · perim=420' PRIOR CHECK WAS WRONG on three items (self-referential area method / marketing SF): • Joist LF: area-method 7,890 FAILED vs CAD bay remasure 8,526 (+8%) • Interior 870 was order-of-mag — CAD corr+demise = 822 • Unit SF 36,080 marketing FAILED vs CAD 35,560 (−520) — east band 28' [PASS] A-EXT Perimeter LF: 420 [PASS] A-EXT Ext wall GROSS/NET: 26,880 / 24,878 · openings 2,002 [PASS] A-EXT Ext studs/floor: 314 (corner-share) · track 840 [ALLOW] A-EXT Opening pack A.6 2,460 LF — still allowance, not A2 CAD [PASS] C-SHAFT Shaft plan 156 LF · 117 pcs/floor [PASS] D-FLOOR Joist LF/floor CAD: 8,526 (was 7,890) · L2–L5 = 34,104 [PASS] D-FLOOR Bridging 8%: 682.1 × 4 = 2,728.4 [PASS] D-FLOOR ALT @24": 22,736 total (do NOT add to 16") [LOCK] D-FLOOR Orientation: units/core span N-S short bay · halls span E-W 6' [PASS] E-ROOF 11,000 SF · joists 5,500 LF @24" [PASS] F-INT Corr+demise CAD: 822 LF/floor (was 870) [ALLOW] F-INT Wet-wall bath: 168 LF/floor allowance (not plate CAD) [PASS] G-PROG GBA 55,000 · keys 56 · baths 64 [FAIL→FIX] G-PROG Unit SF CAD 35,560 ≠ marketing 36,080 (−520) East 28' band: labeled 610→569 · labeled 850→793 [PASS] H-SITE Parking 100 · paving band ~32k SF [INFO] Framing member marks in CALCS = PRELIMINARY · EOR seals fab Source of corrections: geometry.py typical_upper_rooms remasure 2026-07-20 Full write-up: 00-CALCS/TAKEOFF-FRAMING-TRUTH.txt BOQ updated: 05-CFS-TAKEOFF/CFS-TAKEOFF-BOQ.csv